📌 RAID (Storage Redundancy)

Level Method Fault tolerance Notes
RAID 0 Striping None Speed only
RAID 1 Mirroring 1 drive 50% usable capacity
RAID 5 Striping + parity 1 drive Needs 3+ drives
RAID 6 Double parity 2 drives Needs 4+ drives
RAID 10 Mirror + stripe Multiple Speed + redundancy

RAID protects against drive failure — it is not a backup.


📌 Power Protection

Device Role
UPS Battery backup for short outages + power conditioning
Generator Long-term power during extended outages
PDU Distributes power in a rack

📌 Backups

Type Backs up Restore
Full Everything Just the full
Incremental Changes since last backup Full + all incrementals
Differential Changes since last full Full + latest differential

3-2-1 rule: 3 copies, 2 media types, 1 offsite (offline/immutable). Test restores — an untested backup may be unrecoverable.


📌 Disaster Recovery Sites

Site Readiness Cost Recovery time
Hot Fully running, current data Highest Near-instant
Warm Equipped, needs data/activation Medium Hours
Cold Space/power only Lowest Days

RTO = target restore time; RPO = acceptable data loss.


Tip

Key idea — RAID survives drive loss (not a backup). Protect power with UPS/generator. Follow 3-2-1 backups and pick a DR site (hot/warm/cold) to meet your RTO/RPO.